Usage/Application | Fiber Optic Cable Certification |
Model Name/Number | FiberXpert 700 |
Calibrated Wavelength | 850, 980, 1300, 1310, 1490, 1550 and 1625 |
Accuracy | +-0.15 decibels |
Data Storage | up to 10,000 data points |
Temperature Range | -10 to 55 DegreeC |
Weight | 0.4 kg (0.88 lb) |
Distance units | Kilometers, feet, and miles |
Group index range | 1.300000 to 1.700000 in 0.00001 steps |
Number of data points | Up to 128,000 data points |
Distance measurement | Automatic or dual cursor |
Sampling resolution | 4 cm |
Accuracy | +-1 m +- 10-5 x distance +- sampling resolution (excluding group index uncertainties) |
Display range | 1.25 dB to 55 dB |
Display resolution | 0.001 dB |
Cursor resolution | 0.001 dB |
Linearity | +-0.03 dB/dB |
Threshold | 0.01 to 5.99 dB in 0.01 dB steps |
Reflectance accuracy | +-2 dB |
Dimensions (w x h x d) | 128x134x40 mm (5x5.28x1.58 in) |
Interchangeable optical connectors | FC, SC, DIN, and ST |
Laser safety class (21 CFR) | Class 1 |
Operating modes | CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz, TWINTest |
Calibrated wavelengths | MM: 850 and 1300 nm SM: 1310, 1490, 1550, 1625, 1650 nm |
Measurement accuracy | MM: +-1 dB (using a mode conditioner) SM: +-0.5 dB |
Central wavelength (Laser at 25 DegreeC) | MM:850/1300 +-30 nm SM:1310/1550 +-20 nm |
Pulse width | MM:3 ns to 1 SM:3 ns to 20 |
RMS dynamic range | MM:26/24 dB SM:37/35 dB (the one-way difference between the extrapolated backscattering level at the |
Event dead zone | MM:0.8 m SM:0.9 m (measured at +-1.5 dB down from the peak of an unsaturated reflective event) |
Attenuation dead zone | MM:4 m SM:4 m (measured at +-0.5 dB from the linear regression using an F/UPC-type reflectance) |